Site investigation · Geophysics & monitoring

Blast vibration (scaled distance) calculator

Peak particle velocity from charge per delay and distance, and the maximum charge per delay for a PPV limit.

Standard: Scaled distance PPV = K (D/√W)^−β · AS 2187.2 limits (input)

Open the live calculator → All site investigation calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Charge mass per delay25kg
Distance150m
Site constant K1140
Attenuation β1.6
PPV limit10mm/s

Worked example — results

ResultValueUnit
Scaled distance D/√W30.00m/kg^½
PPV4.94mm/s
Max charge for limit60.40kg
D 150 mW 25 kgreceiverSD = 30.0 · PPV = 4.94 mm/s00.5limit 1.0PPV ≤ limit0.49 PASS
Diagram for the worked example

Method, formulas and assumptions

Related site investigation calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.