Timber · Beams & joists

Timber beam / joist (AS 1720.1) calculator

Bending and shear capacity with load-duration factor k1 and long-term deflection with j2 for MGP, F-grade and glulam sections.

Standard: AS 1720.1-2010 · k1 duration · j2 creep

Open the live calculator → All timber calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
GradeMGP12
Breadth b45mm
Depth d240mm
Span4.2m
Dead load (excl. self)0.5kN/m
Live load1.35kN/m
Load duration (governing)5 months (k1 0.8)
Capacity factor φ (category per Table 2.1)0.85
Creep factor j2 (seasoned ≈ 2)2
Deflection limit span /300

Worked example — results

ResultValueUnit
Section modulus Z432×10³ mm³
f'b / E28 MPa / 12700MPa
k10.80
Design load w*2.70kN/m
M* / φMd5.95 / 8.23kNm
V* / φVd5.66 / 17.14kN
Long-term deflection (j2·G + 0.7Q)12.7mm
Limit14.0mm
w* 2.70 kN/mb 45d 240MGP12L 4.2 mM*/φMd 5.95 / 8.23 kNm · δ 12.7 mm (limit 14.0)
Diagram for the worked example

Method, formulas and assumptions

Related timber calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.