Timber · Columns & studs

Timber combined bending & compression calculator

Interaction (M/φMx)² + N/φNcx ≤ 1 and M/φMx + N/φNcy ≤ 1 for a rectangular member.

Standard: AS 1720.1 Cl 3.5

Open the live calculator → All timber calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Design moment4kNm
Design compression20kN
φMx (bending capacity)7.5kNm
φNcx (major axis)110kN
φNcy (minor axis)60kN

Worked example — results

ResultValueUnit
(M/φMx)² + N/φNcx0.466
M/φMx + N/φNcy0.867
Limit1.00
N* 20 kNM* 4 kNm(M*/φMx)² + N*/φNcx = 0.47M*/φMx + N*/φNcy = 0.8700.5limit 1.0Interaction 10.47 PASSInteraction 20.87 PASS
Diagram for the worked example

Method, formulas and assumptions

Related timber calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.