Timber · Columns & studs

Timber column (compression) calculator

Compression capacity with slenderness coefficient S, stability factor k12 and the material constant ρc.

Standard: AS 1720.1 Cl 3.3

Open the live calculator → All timber calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Breadth (minor)90mm
Depth140mm
Effective length (minor axis)2.4m
Characteristic compression f′c22MPa
Capacity factor φ0.85 cat 2
Duration k10.8 (5 months)
Moisture k41
Temperature k61
Material constant ρc1
Design compression N*45kN

Worked example — results

ResultValueUnit
Slenderness S = le/b26.67
k120.281
φNc = φ k1 k4 k6 k12 f′c A53.01kN
N* 45 kNLe 2.4 mb 90d 140Section (mm)φNc = 53.0 kNS = 26.7 · k12 = 0.28100.5limit 1.0N* ≤ φNc0.85 PASS
Diagram for the worked example

Method, formulas and assumptions

Related timber calculators