Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Design shear V*250kN
Moment at splice M*300kNm
Web second moment / total I0.18
Bolt rows4
Bolt columns each side2
Vertical pitch80mm
Column gauge70mm
Joint gap to first column40mm
Web thickness9.1mm
Each web plate thickness8mm
Web plate depth340mm
Plate gradeGrade 250 plate
Bolt sizeM20
Bolt category8.8/S

Worked example — results

ResultValueUnit
Bolt diameter df20.00mm
Bolt tensile strength fuf830.0MPa
Tensile stress area As245.0mm²
Core area Ac (threads)225.0mm²
Shank area Ao314.0mm²
Plate yield stress fy (AS/NZS 3678)280.0MPa
Plate tensile strength fu410.0MPa
Web moment + shear eccentricity72.75kNm
Bolts8.00
Σx²9,800mm²
Σy²64,000mm²
Polar Σ(x² + y²)73,800mm²
x max35.00mm
y max120.0mm
Corner bolt resultant135.3kN
Bolt capacity (double shear, web bearing fu 440)185.3kN
Plates shear 2·0.9·0.6 fy hp t822.5kN
Plates bending 2·0.9 fy t hp²/677.68kNm
V* 250 kN · web M 72.8 kNmcritical bolt 135.3 kN vs capacity 185.3p 8000.5limit 1.0Bolts0.73 PASSPlates shear0.30 PASSPlates bending0.94 PASS
Diagram for the worked example

Method, formulas and assumptions

Related steel calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.