Steel · Connections: moment & splices

Bolted flange splice (cover plates) calculator

Flange force from moment and axial share; outer cover plate tension yield/fracture and short-column compression; bolts in single shear.

Standard: AS 4100 Cl 9.1.4, 7.2, 9.3 (simplified)

Open the live calculator → All steel calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Design moment at splice M*300kNm
Axial force (tension +)0kN
Beam depth460mm
Flange thickness14.5mm
Flange width190mm
Gross section area9520mm²
Cover plate width190mm
Cover plate thickness16mm
Plate gradeGrade 250 plate
Bolts each side of joint (per flange)6
Holes across a section2
Bolt pitch70mm
Bolt sizeM24
Bolt category8.8/S

Worked example — results

ResultValueUnit
Bolt diameter df24.00mm
Bolt tensile strength fuf830.0MPa
Tensile stress area As353.0mm²
Core area Ac (threads)324.0mm²
Shank area Ao452.0mm²
Plate yield stress fy (AS/NZS 3678)250.0MPa
Plate tensile strength fu410.0MPa
Flange force M/(d − tf) + N·bf tf/A673.4kN
Hole diameter26.00mm
Plate gross area3,040mm²
Plate net area2,208mm²
φNt = 0.9 min(Ag fy, 0.85 An fu)684.0kN
Plate λn over 0.6·pitch9.09
φNc (αc ≈ 1 if λn < 25)684.0kN
Bolt group capacity nb·min(φVf, φVb)800.3kN
Cover plate tension: 0.98Cover plate compression: 0.98Bolts: 0.84
Diagram for the worked example

Method, formulas and assumptions

Related steel calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.