Steel · Fire, corrosion & serviceability

Floor vibration from walking (AISC Design Guide 11) calculator

Natural frequency from the deflection of the floor system under its in-service weight, the predicted peak acceleration from walking and the comfort limit for the occupancy.

Standard: AISC DG11 (2nd ed.) · fn = 0.18√(g/Δ) · ap/g = P0·e^(−0.35fn)/(βW) ≤ limit

Open the live calculator → All steel calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Beam deflection under in-service load6mm
Girder deflection under in-service load5mm
Effective panel weight W400kN
Damping ratio β0.03 office with ceiling and services
Acceleration limit0.5 %g offices, residences%g

Worked example — results

ResultValueUnit
Combined deflection Δb + Δg11.00mm
Natural frequency 0.18√(g/Δ)5.38Hz
Peak acceleration 0.29e^(−0.35fn)/(βW)0.368%g
00.5limit 1.0ap/g ≤ limit0.74 PASS
Diagram for the worked example

Method, formulas and assumptions

Related steel calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.