Steel · Connections: moment & splices
Flush end plate moment connection calculator
Bolt tension from elastic distribution about the compression flange, end plate thickness from a double-curvature T-stub, flange welds and shear bolts. Also suits apex joints.
Standard: AS 4100 Cl 9.3, 9.7 · T-stub plate bending (simplified)
Inputs in the worked example
The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.
| Input | Value | Unit |
|---|---|---|
| Design moment M* | 120 | kNm |
| Design shear V* | 90 | kN |
| Beam depth | 360 | mm |
| Beam flange thickness | 11.5 | mm |
| Beam flange width | 171 | mm |
| Bolt row 1 lever arm (from comp. flange centre) | 290 | mm |
| Bolt row 2 lever arm | 210 | mm |
| Bolt row 3 lever arm (0 if none) | 0 | mm |
| Bolt to weld toe distance m | 40 | mm |
| Effective plate width per bolt p | 85 | mm |
| Bolt size | M24 | |
| Bolt category | 8.8/TB | |
| Plate grade | Grade 250 plate | |
| End plate thickness | 25 | mm |
| Flange fillet weld leg | 10 | mm |
| Weld category | SP (φ = 0.8) |
Worked example — results
| Result | Value | Unit |
|---|---|---|
| Bolt diameter df | 24.00 | mm |
| Bolt tensile strength fuf | 830.0 | MPa |
| Tensile stress area As | 353.0 | mm² |
| Core area Ac (threads) | 324.0 | mm² |
| Shank area Ao | 452.0 | mm² |
| Plate yield stress fy (AS/NZS 3678) | 250.0 | MPa |
| Plate tensile strength fu | 410.0 | MPa |
| Σ 2 r² (two bolts per row) | 256,400 | mm² |
| Top bolt tension M r1/Σ2r² | 135.7 | kN |
| φNtf | 234.4 | kN |
| Plate thickness required √(2 T m/(φ fy p)) | 23.83 | mm |
| Number of bolts (tension rows + 2 shear bolts) | 6.00 | |
| Shear per bolt (all bolts) | 15.00 | kN |
| φVf (threads included) | 133.4 | kN |
| Flange force M/(d − tf) | 344.3 | kN |
| Flange weld capacity (both sides of flange) | 568.8 | kN |
| Bolt interaction (V/φVf)² + (N/φNtf)² | 0.348 | |
| Limit | 1.00 |
- ✓ Bolt tension + shear interaction
- ✓ End plate thickness
- ✓ Flange welds
Method, formulas and assumptions
- Bolt diameter df = CHOOSE(4,12,16,20,24,30,36) = 24 mm
- Bolt tensile strength fuf = IF(3=1,400,830) = 830 MPa
- Tensile stress area As = CHOOSE(4,84.3,157,245,353,561,817) = 353 mm²
- Core area Ac (threads) = CHOOSE(4,76.2,144,225,324,519,759) = 324 mm²
- Shank area Ao = CHOOSE(4,113,201,314,452,707,1018) = 452 mm²
- Plate yield stress fy (AS/NZS 3678) = CHOOSE(1,IF(25<=8,280,IF(25<=12,260,250)),IF(25<=8,320,IF(25<=12,310,IF(25<=20,300,280))),IF(25<=12,360,IF(25<=20,350,340))) = 250 MPa
- Plate tensile strength fu = CHOOSE(1,410,430,450) = 410 MPa
- Σ 2 r² (two bolts per row) = 2*(290^2+210^2+0^2) = 2.564e+5 mm²
- Top bolt tension M r1/Σ2r² = 120*1000*290/2.564e+5 = 135.73 kN
- φNtf = 0.8*353*830/1000 = 234.39 kN
- Plate thickness required √(2 T m/(φ fy p)) = SQRT(2*135.73*1000*40/(0.9*250*85)) = 23.827 mm
- Number of bolts (tension rows + 2 shear bolts) = 2*(1+IF(210>0,1,0)+IF(0>0,1,0))+2 = 6
- Shear per bolt (all bolts) = 90/6 = 15 kN
- φVf (threads included) = 0.8*0.62*830*324/1000 = 133.38 kN
- Flange force M/(d − tf) = 120*1000/(360-11.5) = 344.33 kN
- Flange weld capacity (both sides of flange) = IF(1=1,0.8,0.6)*0.6*490*10/SQRT(2)*2*171/1000 = 568.79 kN
- Bolt interaction (V/φVf)² + (N/φNtf)² = (15/133.38)^2+(135.73/234.39)^2 = 0.34795
- Limit = 1 = 1
Related steel calculators
- Bolted moment end plate (extended, 8.8/TB) — Extended end plate on a UB beam framing into a UC column flange. The flange force M*/(d − tf) goes to the…
- Extended end plate (4-bolt unstiffened) — Bolt rows either side of the tension flange share the flange force; plate checked as a T-stub…
- Bolted flange splice (cover plates) — Flange force from moment and axial share; outer cover plate tension yield/fracture and short-column…
- Bolted web splice — Web carries the shear plus its share of moment (Iw/I); double web plates; bolt group polar analysis with…
- Butt-welded splice (CP / IP) — Complete penetration butt weld at parent strength, or incomplete penetration treated as a fillet on the…
- Portal knee: column web panel zone — Shear in the column web panel from the rafter moment; diagonal stiffener area required if the web is…
For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.