Steel · Fire, corrosion & serviceability

Deflection limits checker calculator

Maximum deflection of simply supported, propped, fixed or cantilever members under UDL and point load, against selectable limits.

Standard: AS/NZS 1170.0 Appendix C (typical limits)

Open the live calculator → All steel calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
SupportSimply supported
Span6m
Service UDL8kN/m
Service point load (mid / tip)0kN
E200000MPa
I142000000mm⁴
Limit span/L/250 general floors

Worked example — results

ResultValueUnit
UDL coefficient0.013
Point load coefficient0.021
Deflection4.75mm
Limit24.00mm
w 8 kN/mδ = 4.75 mm (limit L/250 = 24.0)L 6 m00.5limit 1.0Deflection within limit0.20 PASS
Diagram for the worked example

Method, formulas and assumptions

Related steel calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.