Retaining & slopes · Gravity & cantilever walls

Cantilever retaining wall: L, inverted-T or counterfort, with reinforcement calculator

Reinforced concrete retaining wall as an L-shape (no toe), inverted-T or counterfort wall. Stability by Rankine active pressure on the vertical plane through the heel: sliding, overturning, eccentricity and bearing. Reinforcement from the AS 3600 rectangular stress block for the stem (cantilever, or spanning horizontally between counterforts), the heel and the toe, plus the counterfort tie.

Standard: AS 4678 earth-retaining structures · AS 3600 · Rankine active pressure · GEO5 Cantilever Wall style

Open the live calculator → All retaining & slopes calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Wall typeInverted-T (toe and heel)
Total height, underside of base to top of fill4.5m
Base thickness0.4m
Stem thickness at base0.35m
Stem thickness at top0.25m
Toe length0.8m
Heel length (behind the stem)2.3m
Counterfort spacing (counterfort wall)3m
Counterfort thickness0.3m
Backfill γ19kN/m³
Backfill φ′32°
Surcharge on the fill10kPa
Base friction coefficient tan δb0.5
Allowable bearing pressure200kPa
Concrete f′c32MPa
Reinforcement fsy500MPa
Cover50mm
Bar diameter16mm
Required FS sliding1.5
Required FS overturning2

Worked example — results

ResultValueUnit
Ka (Rankine)0.307
Active thrust Pa72.9kN/m
Vertical load ΣV (excl. surcharge)241.8kN/m
FS sliding1.66
FS overturning4.16
Eccentricity e (B/6 = 0.58)0.094m
Bearing qmax / qmin89 / 64kPa
Stem base M*139.3kNm/m
Stem steel (vertical, back face)1,168 mm²/m → N16 @ 150
Heel M* (top steel)98.9kNm/m
Heel steel762 mm²/m → N16 @ 250
Toe M* (bottom steel)36.9kNm/m
Toe steel762 mm²/m → N16 @ 250
Pa 73 kN/mB 3.45 mq 89 / 64 kPa
Diagram for the worked example

Method, formulas and assumptions

Related retaining & slopes calculators