Concrete · Columns & walls

Slender RC column (moment magnifier) calculator

Slenderness, buckling load Nc, moment magnifier δb and the magnified design moment checked against the N–M interaction diagram for a braced rectangular column.

Standard: AS 3600 Cl 10.3–10.4 braced columns · δb = km/(1 − N*/Nc)

Open the live calculator → All concrete calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Width b400mm
Depth D (bending direction)400mm
Number of bars (two faces)8
Bar diameter20mm
Cover40mm
Tie diameter10mm
f′c40MPa
fsy500MPa
Design axial load N*1500kN
Larger end moment M2*60kNm
M1*/M2* (negative = single curvature)-0.5
Effective length Le4.5m
Sustained-load ratio βd = G/(G + Q)0.6

Worked example — results

ResultValueUnit
Slenderness Le/r (r = 0.3D)37.5
Short-column limit25.0
Column typeSlender
Balanced moment Mub392.6kNm
Buckling load Nc4,810kN
km0.800
Moment magnifier δb1.163
Minimum moment N*·0.05D30.0kNm
Design moment69.8kNm
φMu at N*250.0kNm
010020030040002e34e36e3M (kNm)N (kN)M* = 70 kNmNu–MuφNu–φMu
Diagram for the worked example

Method, formulas and assumptions

Related concrete calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.