Concrete · Special elements
Corbel (strut-and-tie) calculator
Single strut-and-tie model: tie force including horizontal restraint, tie steel, strut angle and strut stress with βs.
Standard: AS 3600 Ch 7 (strut-and-tie), Cl 12.? corbel detailing (simplified)
Inputs in the worked example
The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.
| Input | Value | Unit |
|---|---|---|
| Vertical load V* | 400 | kN |
| Horizontal restraint (≥ 0.2V) | 80 | kN |
| Load to column face av | 200 | mm |
| Effective depth at face | 500 | mm |
| Corbel width | 400 | mm |
| Bearing plate width (strut width basis) | 150 | mm |
| f′c | N40 | MPa |
| fsy | 500 | MPa |
| Tie steel provided | 1200 | mm² |
Worked example — results
| Result | Value | Unit |
|---|---|---|
| Lever arm ≈ 0.8 d | 400.0 | mm |
| Strut angle atan(z/av) | 63.43 | ° |
| Tie force V av/z + H | 280.0 | kN |
| Tie steel T/(0.8 fsy) | 700.0 | mm² |
| Strut force V/sin θ | 447.2 | kN |
| βs = 1/(1 + 0.66 cot²θ) (0.3 … 1.0) | 0.858 | |
| φ strut capacity 0.6·βs·0.9f′c·b·wb sinθ | 995.0 | kN |
- ✓ Tie steel adequate
- ✓ Strut capacity
- ✓ Strut angle ≥ 30°
Method, formulas and assumptions
- Lever arm ≈ 0.8 d = 0.8*500 = 400 mm
- Strut angle atan(z/av) = DEGREES(ATAN(400/200)) = 63.435 °
- Tie force V av/z + H = 400*200/400+80 = 280 kN
- Tie steel T/(0.8 fsy) = 280*1000/(0.8*500) = 700 mm²
- Strut force V/sin θ = 400/SIN(RADIANS(63.435)) = 447.21 kN
- βs = 1/(1 + 0.66 cot²θ) (0.3 … 1.0) = MIN(1,MAX(0.3,1/(1+0.66/TAN(RADIANS(63.435))^2))) = 0.85837
- φ strut capacity 0.6·βs·0.9f′c·b·wb sinθ = 0.6*0.85837*0.9*40*400*150*SIN(RADIANS(63.435))/1000 = 995 kN
Related concrete calculators
- Development & lap length — Development length of deformed bars in tension and tension lap length.
- Staircase (waist slab) — Self-weight of steps and waist, bending reinforcement for a flight spanning horizontally, and riser/going…
- Circular water tank wall — Hydrostatic hoop tension, hoop reinforcement for a limiting steel stress and stored volume.
- Corbel or nib: strut-and-tie design — Short cantilever (av/d ≤ 1) carrying a vertical reaction V* and a horizontal restraint force H* (≥ 0.2V* for…
- Concrete bearing stress — Bearing capacity under a plate with the √(A2/A1) enhancement capped at 2.0.
- RC beam (flexure + shear) — Singly reinforced rectangular beam: tension steel, ductility and shear with stirrups.
For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.