Foundations · Pile testing & NDT

Thermal integrity profiling (TIP): effective diameter and cover calculator

Converts the average temperature at an anomaly to an effective radius, estimates cover to the cage and the cage offset from the spread between wires.

Standard: ASTM D7949 · temperature ∝ effective radius (linear model)

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Nominal diameter1m
Cage diameter (to thermal wires)0.75m
Soil (ambient) temperature22°C
Average temperature in sound shaft52°C
Average temperature at anomaly51°C
Hottest wire at anomaly52°C
Coolest wire at anomaly50°C
Specified minimum cover75mm

Worked example — results

ResultValueUnit
Effective radius (D/2)(Ta − Ts)/(Tb − Ts)0.483m
Average cover re − dc/2108.3mm
Radius per °C (D/2)/(Tb − Ts)16.67mm/°C
Cage offset ≈ k(Tmax − Tmin)/216.67mm
Cover on the tight side91.67mm
Check: De / D0.967
Effective diameter0.967m
nominal 1 m (dashed) · effective 0.97 mcover 108 mm avgtight side 92 mmcage offset 17 mm
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators