Foundations · Pile testing & NDT

Crosshole sonic logging: profile rating calculator

Rates every reading of one tube-pair profile against the median first arrival time (FAT) and energy: Good ≤ 10 % / < 6 dB, Questionable ≤ 20 % / < 9 dB, Poor/Flaw ≤ 30 % / < 12 dB, otherwise Poor/Defect.

Standard: ASTM D6760 · FAT increase / energy reduction rating (Good, Questionable, Poor/Flaw, Poor/Defect)

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Tube spacing (centre to centre)0.8m
Readings: depth (m), FAT (μs), relative energy (dB)1, 200, -0.4 2, 200, -1.3 3, 200, -0.2 4, 198, -1.0 5, 200, -0.3 6, 199, -0.6 7, 200, -0.4 8, 201, -1.5 9, 200, 0 10, 202, -0.5 11, 250, -10.0 12, 224, -5.0 13, 200, -0.3 14, 198, -1.3 15, 200, -0.2 16, 198, -0.1 17, 200, -0.5 18, 201, -1.4 19, 200, -0.2 20, 202, -0.9

Worked example — results

ResultValueUnit
Median FAT (sound concrete reference)200.0μs
Median energy-0.500dB
Median velocity s/FATm4,000m/s
Questionable readings1.00
Poor/Flaw readings1.00
Poor/Defect readings0.000
Depth of worst reading11.00m
Worst FAT increase25.00%
20021022023024025005101520FAT (μs)Depth (m)
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.