Ground engineering · Rock mechanics

Point load index (rock) calculator

Is and size-corrected Is(50) for diametral or axial/block tests, AS 1726 strength term and estimated UCS.

Standard: AS 4133.4.1 · size correction (De/50)^0.45 · AS 1726 strength terms

Open the live calculator → All ground engineering calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
TestDiametral (core)
Failure load P6.4kN
Core diameter / platen separation D63mm
Width W (axial / block)60mm
UCS / Is(50) factor K20

Worked example — results

ResultValueUnit
Equivalent core diameter De63.0mm
Uncorrected Is1.61MPa
Size correction F1.110
Is(50)1.79MPa
Strength term (AS 1726)high
Estimated UCS = K·Is(50)36MPa
ext. low0.03v. low0.1low0.3medium1high3v. high10ext. high30Is(50) = 1.79 MPaUCS ≈ 36 MPa (K = 20)
Diagram for the worked example

Method, formulas and assumptions

Related ground engineering calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.