Foundations · Pile capacity

Neutral plane, drag force and downdrag settlement (unified method) calculator

Single pile through settling ground. The load curve (dead load plus accumulated negative friction from the top) and the resistance curve (toe resistance plus positive shaft friction from the bottom) intersect at the neutral plane. The drag force is the load gained above it, the maximum pile load is checked against the structural capacity (live load is not added to drag), and the pile settles as much as the ground does at the neutral plane plus elastic shortening.

Standard: Fellenius unified design method (2004, 2020) · AS 2159 Cl 4.4 negative friction · settlement at the neutral plane

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Shaft resistance: bottom depth (m), unit shaft resistance (kPa)6, 15 14, 30 24, 60
Diameter0.5m
Length24m
Dead load900kN
Live load300kN
Toe resistance mobilised600kN
Ground settlement at the surface (long term)120mm
Depth where ground settlement becomes zero18m
Pile modulus30000MPa
Structural design capacity φNs3500kN
Allowable pile settlement30mm

Worked example — results

ResultValueUnit
Neutral plane depth14.66m
Drag force580kN
Maximum pile load (at the neutral plane)1,480kN
Ground settlement at the neutral plane22.3mm
Elastic shortening4.5mm
Pile head settlement26.8mm
Dead + live load (no drag) for geotechnical check1,200kN
05001e32e32e33e305101520Load / resistance (kN)Depth (m)neutral planeLoad (dead + drag)Resistance (toe + shaft below)
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.