Foundations · Pile capacity

Pile capacity and settlement from CPT (LCPC method) calculator

Pile designed directly from a cone penetration test, as in the GEO5 Pile CPT program. The equivalent base resistance qca is the mean qc within 1.5D above and below the toe, clipped to 0.7–1.3 times that mean; qb = kc·qca. Shaft friction in each reading is qc/α limited by the LCPC maximum for clay/silt or sand/gravel and bored or driven piles. The design capacity uses φg, and the settlement at the working load uses the Randolph–Wroth stiffness with soil modulus from qc.

Standard: Bustamante & Gianeselli (1982) LCPC method · AS 2159-2009 φg · Randolph & Wroth (1978) head stiffness with E = αE·qc

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
CPT: depth (m), qc (MPa), soil (1 = clay/silt, 2 = sand/gravel)0.5, 0.85, 1 1.0, 0.90, 1 1.5, 0.95, 1 2.0, 1.00, 1 2.5, 1.05, 1 3.0, 1.10, 1 3.5, 1.15, 1 4.0, 1.60, 1 4.5, 1.68, 1 5.0, 1.75, 1 5.5, 1.83, 1 6.0, 1.90, 1 6.5, 1.98, 1 7.0, 2.05, 1 7.5, 2.13, 1 8.0, 2.20, 1 8.5, 2.27, 1 9.0, 2.35, 1 9.5, 2.42, 1 10.0, 2.50, 1 10.5, 2.58, 1 11.0, 2.65, 1 11.5, 2.73, 1 12.0, 9.00, 2 12.5, 9.40, 2 13.0, 9.80, 2 13.5, 10.20, 2 14.0, 10.60, 2 14.5, 11.00, 2 15.0, 11.40, 2 15.5, 11.80, 2 16.0, 12.20, 2 16.5, 12.60, 2 17.0, 13.00, 2 17.5, 13.40, 2 18.0, 13.80, 2 18.5, 14.20, 2 19.0, 14.60, 2 19.5, 15.00, 2 20.0, 15.40, 2
Pile typeBored / CFA (LCPC category I)
Diameter0.6m
Length (toe depth)16m
Geotechnical reduction φg0.5
Design load N*800kN
Working (serviceability) load600kN
Pile modulus30000MPa
Soil modulus factor E = αE·qc3
Soil Poisson's ratio0.3
Allowable settlement15mm

Worked example — results

ResultValueUnit
Mean qc within ±1.5D of the toe12.20MPa
Equivalent qca (clipped 0.7–1.3)12.20MPa
Base factor kc0.15
Base resistance qb / Rb1,830 kPa / 517 kN
Shaft resistance Rs1,252kN
Ultimate capacity Rug1,769kN
Design capacity φg·Rug885kN
Average shaft modulus / base modulus12.8 / 36.6MPa
Head stiffness (Randolph–Wroth)121MN/m
Settlement at the working load4.9mm
qca 12.20 MPaN* 800 kN0204060800246810121416Unit shaft friction (kPa)Depth (m)
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.