Foundations · Pile groups & caps

Pile cap (2/3/4 piles) calculator

Truss-method tie force and steel, strut angle, pile load and column punching.

Standard: AS 3600 Ch 7 strut-and-tie · Cl 9.3 punching · AS 2159

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Number of piles4 piles
Column load N*4000kN
Pile spacing1.8m
Pile diameter600mm
Cap depth1000mm
Column size500mm
Cover75mm
Tie bar diameter20mm
f'c32MPa
fsy500MPa
Pile design capacity φRd,g1200kN

Worked example — results

ResultValueUnit
d (to tie)895mm
Load per pile1,000kN
Tie force T*1,006kN
Tie locationeach direction (over the piles)
Ast per tie (φ = 0.8)2,514mm²
Bars per tie9 N20
Strut angle35°
Column punching φVuo6,724kN
Plan: ties solid, struts dashedθ = 35°Elevation
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.