Foundations · Pile capacity

Negative skin friction (downdrag) calculator

Drag load on a pile from a settling layer (fill over soft clay) by the β method, and the maximum axial force at the neutral plane.

Standard: Effective-stress β method · drag load in the settling layer

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Pile diameter0.6m
Depth of settling soil8m
Effective unit weight γ′8kN/m³
Fill surcharge30kPa
β (clay 0.2–0.3)0.25
Dead load on pile900kN
Structural capacity φNs2600kN

Worked example — results

ResultValueUnit
Perimeter πD1.885m
Drag load Qn234kN
σ′v at base of settling layer94kPa
Max axial force QD + Qn1,134kN
Hs = 8 mD 0.6 mfill q = 30 kPa
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.