Concrete · Materials & serviceability

Concrete cores: corrected strength and acceptance calculator

Core compressive strengths corrected for length/diameter ratio, the mean and the lowest, against the usual in-situ acceptance criteria.

Standard: AS 1012.14 core testing · L/D correction (ASTM C42) · acceptance: mean ≥ 0.85f′c and each ≥ 0.75f′c (ACI 318 26.12.6)

Open the live calculator → All concrete calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Specified f′c32MPa
Cores: id, length (mm), diameter (mm), failure load (kN)C1, 190, 94, 213 C2, 160, 94, 205 C3, 140, 94, 196

Worked example — results

ResultValueUnit
Lowest corrected27.08MPa
Limit: 0.85f′c (mean)27.20MPa
Limit: 0.75f′c (each)24.00MPa
Mean corrected28.87MPa
00.5limit 1.0Mean ≥ 0.85f′c0.94 PASSEach core ≥ 0.75f′c0.89 PASS
Diagram for the worked example

Method, formulas and assumptions

Related concrete calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.