Retaining & slopes · Reinforced soil & gabions

MSE wall with steel strips calculator

External sliding, overturning and bearing, plus Kr, maximum tension, pull-out and tension checks at every strip layer of an inextensible-reinforcement wall.

Standard: FHWA-NHI-10-024 simplified method · AS 4678 concepts

Open the live calculator → All retaining & slopes calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Wall height H6m
Strip length L4.8m
Vertical spacing Sv0.75m
Horizontal strip spacing Sh0.75m
Strip width b50mm
Allowable tension per strip (after corrosion loss)40kN
Pull-out factor F* at the top (≤ 2.0)2
Reinforced fill γ20kN/m³
Reinforced fill φ′34°
Retained soil γ19kN/m³
Retained soil φ′30°
Foundation φ′30°
Foundation γ19kN/m³
Surcharge q10kPa
SurchargePermanent (counts for pull-out)

Worked example — results

ResultValueUnit
Ka (fill) / Ka (retained)0.283 / 0.333
Layers8
Max strip tension Tmax23.99kN
Lowest pull-out FS1.77at z = 5.63 m
Sliding FS2.48
Overturning FS4.80
Eccentricity e (limit L/6 = 0.80)0.500m
Bearing pressure (Meyerhof)161kPa
Ultimate bearing825kPa
Bearing FS5.13
2.172.061.941.811.791.861.851.77max tension lineL = 4.8 mH 6 m
Diagram for the worked example

Method, formulas and assumptions

Related retaining & slopes calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.