Construction & estimating · Site operations

Concrete maturity (strength in place) calculator

Temperature–time factor and equivalent age from logged temperatures, and estimated in-place strength from a calibration S = a + b·log10(M).

Standard: ASTM C1074 · Nurse-Saul TTF and Arrhenius equivalent age

Open the live calculator → All construction & estimating calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Log: interval Δt (h), mean T (°C)6, 22 6, 28 6, 31 6, 26 12, 20 12, 18 24, 17
Datum temperature T0-10°C
Activation energy Ea40000J/mol
Reference temperature20°C
Calibration a-38MPa
Calibration b19MPa
Strength required to strip15MPa

Related construction & estimating calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.