Masonry · Reinforced masonry

Reinforced masonry wall: out-of-plane bending calculator

Bending capacity per metre of a reinforced core-filled block wall, with the steel ratio limit.

Standard: AS 3700 Cl 8.6

Open the live calculator → All masonry calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Steel area per metre565mm²/m
Effective depth95mm
fsy500MPa
f′m (grouted)8MPa
Design moment15kNm/m

Worked example — results

ResultValueUnit
Effective steel (≤ 0.29·1.3 f′m b d/fsy)565.0mm²/m
Md = φ fsy As d (1 − 0.6 fsy As/(1.3 f′m b d))16.67kNm/m
d 95 mmAs 565 mm²/mφMd = 16.67 kNm/mM* = 15 kNm/m00.5limit 1.0M* ≤ Md0.90 PASS
Diagram for the worked example

Method, formulas and assumptions

Related masonry calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.