Analysis & loading · Wind, snow & cyclone

Wind pressure on cladding & fixings calculator

Design pressure for a cladding element from Vdes, external and internal coefficients, area reduction and local pressure factor; fixing load.

Standard: AS/NZS 1170.2 Cl 2.4, 5.4 (p = 0.5ρV²Cfig Cdyn)

Open the live calculator → All analysis & loading calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Design wind speed Vdes,θ45m/s
External pressure coefficient Cp,e-0.9
Area reduction Ka1
Combination factor Kc1
Local pressure factor Kl2.0 (RA2)
Internal coefficient Cp,i0.2
Fixing tributary area0.6m²
Fixing capacity1.5kN

Worked example — results

ResultValueUnit
0.5 ρ V² (ρ = 1.2)1.22kPa
Cfig,e = Cp,e Ka Kc Kl-1.80
Net pressure q(Cfig,e − Cp,i Kc)-2.43kPa
Fixing load |p| A1.46kN
p = -2.43 kPa(suction for Cp,e < 0)q = 1.215 kPafixing area A = 0.6 m²F* = 1.46 kN (Rf 1.5)00.5limit 1.0Fixing capacity0.97 PASS
Diagram for the worked example

Method, formulas and assumptions

Related analysis & loading calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.