Site investigation · Laboratory: soil classification

Liquid limit: cone penetrometer calculator

Linear fit of moisture content against cone penetration; the liquid limit is w at 20 mm penetration.

Standard: AS 1289.3.9.1 · BS 1377-2

Open the live calculator → All site investigation calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Points: penetration (mm), moisture (%)15.2, 38.1 17.9, 40.6 21.4, 43.2 24.8, 46.0

Worked example — results

ResultValueUnit
Slope dw/dp0.813%/mm
Intercept25.86%
Liquid limit (w at 20 mm)42.12%
Fit R²0.998
141618202224263840424446Cone penetration (mm)w (%)LL 42.1%
Diagram for the worked example

Method, formulas and assumptions

Related site investigation calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.