Site investigation · Laboratory: soil classification

Liquid limit: Casagrande cup calculator

Flow curve (w against log N) by least squares; LL at 25 blows and the flow index.

Standard: AS 1289.3.1.1 · ASTM D4318

Open the live calculator → All site investigation calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Points: blows N, moisture (%)34, 47.2 27, 49.0 21, 50.9 16, 52.8

Worked example — results

ResultValueUnit
Slope dw/dlogN-17.12%
Intercept73.47%
Liquid limit at 25 blows49.54%
Flow index (per log cycle)17.12%
1010040455055Number of blows Nw (%)LL 49.5
Diagram for the worked example

Method, formulas and assumptions

Related site investigation calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.