Foundations · Pad, strip & combined footings

Strip footing with eccentric load calculator

Strip footing under a wall with moment: eccentricity, effective width B′, trapezoidal pressure and ultimate bearing on B′.

Standard: Meyerhof effective width · Vesic factors

Open the live calculator → All foundations calculators

Inputs in the worked example

The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.

InputValueUnit
Footing width1.2m
Founding depth0.6m
Vertical load per metre (service)150kN/m
Moment per metre20kNm/m
Cohesion c′5kPa
Friction angle φ′30°
Unit weight γ18kN/m³
Required FS3

Worked example — results

ResultValueUnit
e = M/N0.133m
B′ = B − 2e0.933m
qmax = N/B(1 + 6e/B)208.3kPa
qmin41.67kPa
Nq18.40
Nc30.14
Nγ22.40
qult = cNc + γDf Nq + 0.5γB′Nγ537.6kPa
q on B′ = N/B′160.7kPa
FS = qult/(N/B′)3.35
N 150 kN/mM 20qmax 208qmin 42 kPaDf 0.6 mB 1.2 mB′ 0.93 me = 0.133 m · FS = 3.35
Diagram for the worked example

Method, formulas and assumptions

Related foundations calculators

For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.