Spread footing from CPT: bearing and settlement calculator
Pad or strip footing designed directly from a CPT, as in GEO5 Spread Footing CPT. The equivalent cone resistance qce is the mean qc from the founding level to 1.5B below, clipped at 1.3 times that mean; the bearing factor kc grows with the equivalent embedment De/B and the footing shape. Design bearing uses φg. Settlement follows Schmertmann's strain-influence method with E = 2.5qc (square) to 3.5qc (strip), depth and creep corrections.
Standard: Direct CPT method (Frank 1999 / EN 1997-2 Annex D): q = kc·qce + q0 · Schmertmann (1978) strain-influence settlement · AS 2159-style φg
Inputs in the worked example
The live calculator starts with these values; change any of them and every result, check and diagram updates instantly.
| Input | Value | Unit |
|---|---|---|
| CPT: depth (m), qc (MPa) | 0.25, 2.89 0.50, 3.68 0.75, 4.26 1.00, 4.59 1.25, 4.65 1.50, 4.49 1.75, 4.17 2.00, 3.82 2.25, 3.53 2.50, 3.41 2.75, 3.53 3.00, 3.91 3.25, 4.54 3.50, 5.36 3.75, 6.26 4.00, 7.14 4.25, 7.89 4.50, 8.42 4.75, 8.69 5.00, 8.70 5.25, 8.49 5.50, 8.16 5.75, 7.81 6.00, 7.55 6.25, 7.48 6.50, 7.65 6.75, 8.09 7.00, 8.77 7.25, 9.62 7.50, 10.52 7.75, 11.38 8.00, 12.09 8.25, 12.57 8.50, 12.78 8.75, 12.73 9.00, 12.50 9.25, 12.15 9.50, 11.81 9.75, 11.58 10.00, 11.56 | |
| Soil | Sand / gravel (kc0 = 0.14) | |
| Footing width B | 2.4 | m |
| Footing length L (= B for square) | 2.4 | m |
| Founding depth D | 1 | m |
| Soil unit weight | 18 | kN/m³ |
| Geotechnical reduction φg | 0.5 | |
| Design vertical load N* | 1300 | kN |
| Service load (net of soil removed) | 700 | kN |
| Time for creep factor | 25 | yr |
| Allowable settlement | 25 | mm |
Worked example — results
| Result | Value | Unit |
|---|---|---|
| Mean qc, D to D + 1.5B | 5.05 | MPa |
| Equivalent qce (clipped at 1.3 × mean) | 4.80 | MPa |
| Equivalent embedment De | 0.80 | m |
| Bearing factor kc | 0.156 | |
| Ultimate bearing kc·qce + q0 | 768 | kPa |
| Design resistance φg·qult·A | 2,212 | kN |
| Net service pressure Δp | 122 | kPa |
| Peak strain influence Izp at 1.20 m | 0.675 | |
| C1 (embedment) / C2 (creep) | 0.926 / 1.480 | |
| Schmertmann settlement | 24.4 | mm |
- ✓ N* ≤ φg·R — 59 %
- ✓ Settlement ≤ allowable — 24.4 mm
- ✓ CPT reaches the bottom of the influence zone (D + 2B)
Method, formulas and assumptions
- qce = mean of min(qc, 1.3·mean) over D to D + 1.5B; De = (1/qce)∫₀ᴰ qc dz.
- kc = kc0[1 + 0.35(0.6 + 0.4B/L)De/B], kc0 = 0.32 clay/silt, 0.14 sand/gravel (simplified from EN 1997-2 Annex D.3 / Frank 1999); qult = kc·qce + γD.
- Schmertmann: s = C1·C2·Δp·Σ(Iz/E)Δz, Izp = 0.5 + 0.1√(Δp/σ′vp), E = 2.5qc square / 3.5qc strip, C1 = 1 − 0.5σ′0/Δp, C2 = 1 + 0.2log(t/0.1).
Related foundations calculators
- Pad footing — Square pad: bearing, flexural steel, one-way shear and punching shear.
- Bearing capacity — Ultimate and allowable bearing pressure for strip or rectangular footings with shape and depth factors.
- Strip footing with eccentric load — Strip footing under a wall with moment: eccentricity, effective width B′, trapezoidal pressure and ultimate…
- Combined footing (two columns) — Length placing the resultant at the centroid (uniform pressure), width for allowable bearing, and maximum…
- Strap (cantilever) footing — Exterior footing eccentric to a boundary column connected by a strap to an interior footing: reactions…
- Footing uplift resistance — Uplift capacity from footing self-weight plus the soil frustum spreading at angle α, against wind uplift.
For preliminary design and education. Check every result against the current standard and your own engineering judgement before use.